精度
|
1.0% F.S. < 20 SLPM
1.5% F.S. 20-50 SLPM
|
1.0% F.S. < 20 SLPM
1.5% F.S. 20-50 SLPM
|
1% full scale including linearity at calibrated conditions
|
1% full scale including linearity at calibrated conditions
|
1% full scale including linearity at calibrated conditions
|
1% full scale including linearity at calibrated conditions
|
Response Time - NC
|
E Series: < 3 seconds within 2% of full scale (0-100% command step)
I Series: 6 seconds within 2% of full scale (0-100% command step)
|
E Series: < 3 seconds within 2% of full scale (0-100% command step)
I Series: 6 seconds within 2% of full scale (0-100% command step)
|
E Series: < 3 seconds within 2% of full scale (0-100% command step)
I Series: 6 seconds within 2% of full scale (0-100% command step)
|
E Series: < 3 seconds within 2% of full scale (0-100% command step)
I Series: 6 seconds within 2% of full scale (0-98% command step)
|
E Series: < 3 seconds within 2% of full scale (0-100% command step)
I Series: 6 seconds within 2% of full scale (0-100% command step)
|
E Series: < 3 seconds within 2% of full scale (0-100% command step)
I Series: 6 seconds within 2% of full scale (0-100% command step)
|
アナログ通信
|
E Series: 0-5 Vdc
I Series: 0-5 Vdc; 0-20 mA; 4-20 mA
|
E Series: 0-5 Vdc
I Series: 0-5 Vdc; 0-20 mA; 4-20 mA
|
E Series: 0-5 Vdc
I Series: 0-5 Vdc; 0-20 mA; 4-20 mA
|
E Series: 0-5 Vdc
I Series: 0-5 Vdc; 0-20 mA; 4-20 mA
|
E Series: 0-5 Vdc
I Series: 0-5 Vdc; 0-20 mA; 4-20 mA
|
E Series: 0-5 Vdc
I Series: 0-5 Vdc; 0-20 mA; 4-20 mA
|