3809G
|
3809G ELF
|
3809G TFE Lined
|
3810G
|
Unterscheidungsmerkmal
|
Flow Meter
|
Flow Meter
|
Flow Meter
|
Flow Meter
|
Art des Mediums
|
Clean Liquids
Gas
Steam
|
Clean Liquids
Gas
Steam
|
Clean Liquids
Gas
Steam
|
Clean Liquids
Gas
Steam
|
Durchflussbereich (Maximalwert)
|
Flow Range - Water: 440 GPM / 100,000 l/h
Flow Range - Air: 750 SCFM / 1200 m3n/hr
|
Flow Range - Water: 11 GPH / 42 l/h
Flow Range - Air: 53 SCFH / 1.4 m3n/hr
|
Flow Range - Water: 66 GPM / 15,000 l/h
Flow Range - Air: 280 SCFM / 470 m3n/hr
|
Flow Range - Water: 88 GPM / 20,000 l/h
Flow Range - Air: 390 SCFM / 650 m3n/hr
|
Genauigkeit
|
+/- 2% Full Scale / Class 1.6 VDI / VDE
+/- 1% Full Scale
|
+/- 5% Full Scale / Class 4 VDI / VDE
+/- 3% Full Scale / Class 2.5 VDI / VDE
|
+/- 2% Full Scale / Class 1.6 VDI / VDE
|
+/- 5% Full Scale / Class 4 VDI / VDE
+/- 3% Full Scale / Class 2.5 VDI / VDE
|
Maximaler Druck
|
6000 PSIG / 413.7 bar
|
6000 PSIG / 413.7 bar
|
Based on selected flange rating
|
2567 PSIG / 177 bar
|
Medienberührte Teile
|
316 / 316L Stainless Steel, Alloy 625, Hastelloy C-276, Titanium GR II
|
316 / 316L Stainless Steel, Alloy 625, Hastelloy C-276, Titanium GR II
|
316/316L Stainless Steel with Tefzel lining
|
316 / 316L Stainless Steel,
|
Prozessanschluss
|
All materials: NPT, Rc (BSP) Female
All materials: 150#, 300#, 600# Flanges per ASME B16.5
All materials: DIN PN40 Flanges
All materials: JIS B2220 DIN 10K, 20K Flanges
|
All materials: NPT, Rc (BSP) Female
All materials: 150#, 300#, 600# Flanges per ASME B16.5
All materials: DIN PN40 Flanges
All materials: JIS B2220 DIN 10K, 20K Flanges
|
NPT (Female)
|
NPT, Rc (BSP) Female
150#, 300# Flanges per ASME B16.5
DIN PN40 Flanges
|
Analoge Kommunikation
|
Transmitter
4-20 mA Output
|
Transmitter
4-20 mA Output
|
Transmitter
4-20 mA Output
|
None
|
Digitale Kommunikation
|
HART® 7
FOUNDATIONTM Fieldbus
|
HART® 7
FOUNDATIONTM Fieldbus
|
HART® 7
FOUNDATIONTM Fieldbus
|
HART® 7
FOUNDATIONTM Fieldbus
|
Alarme
|
One or two inductive switches - All Sizes
|
One or two alarm contacts with transmitter - All Sizes
|
One or two inductive switches - All Sizes
|
None
|
Zertifikate und Zulassungen
|
Indicator
IP66/67, NEMA 4X
Flame Proof
IP66/67, NEMA 4X
Intrinsic Safety / Non-sparking / Enclosure Dust / Aluminum housing
IP64
Intrinsic Safety / Non-sparking / Enclosure Dust / 316 Stainless Steel housing
IP66/67
International agency approvals for alarm and transmitter
SIL 2 for alarm option
International Calibration Certificate (ICC)
Material certifications
Liquid Dye Penetrant
Positive Material Identification
NACE MR 01-75 & MR 0103
|
Indicator
IP66/67, NEMA 4X
Flame Proof
IP66/67, NEMA 4X
Intrinsic Safety / Non-sparking / Enclosure Dust / Aluminum housing
IP64
Intrinsic Safety / Non-sparking / Enclosure Dust / 316 Stainless Steel housing
IP66/67
International agency approvals for alarm and transmitter
International Calibration Certificate (ICC)
Material certifications
Liquid Dye Penetrant
Positive Material Identification
NACE MR 01-75 & MR-0103
|
Indicator
IP66/67, NEMA 4X
Flame Proof
IP66/67, NEMA 4X
Intrinsic Safety / Non-sparking / Enclosure Dust / Aluminum housing
IP64
Intrinsic Safety / Non-sparking / Enclosure Dust / 316 Stainless Steel housing
IP66/67
International agency approvals for alarm and transmitter
SIL 2 for alarm option
International Calibration Certificate (ICC)
Material certifications
Liquid Dye Penetrant
Positive Material Identification
NACE MR 01-75 & MR 0103
Pressure Test certificate
Oxygen Cleaning certificate
Certificate of Conformance
|
Indicator
IP66/67, NEMA 4X
International Calibration Certificate (ICC)
Material certifications
|
Zertifikate für Funktionale Sicherheit
|
SIL 2 - Alarms
|
None
|
SIL 2 - Alarms
|
None
|