Unterscheidungsmerkmal
Ultra-High Purity
Druckbereich
-15 psi - 3000 psi
Berstdruck
400% full scale
Druckfest
200% full scale up to 2,000 psi, 150% full scale for higher ranges
Genauigkeit
0.25% Full Scale (BFSL)
Ansprechzeit – Stromlos geschlossenes Ventil
< 5 msec
Temperaturkoeffizient
>100 PSI Ranges: Full Scale:+0.02% full scale/OF (-4OF to 140OF, -20OC to 60OC)
+0.50% full scale (68OF to 140OF, 20OC to 60OC) 0 to 10 Vdc version
<100 PSI Ranges: Full Scale:+0.04% full scale/OF (-4OF to 140OF, -20OC to 60OC)
+1.00% full scale (68OF to 140OF, 20OC to 60OC) 0 to 10 Vdc version
Verwendete Materialien
Housing: Stainless steel, polymer plastics
Oberflächenbeschaffenheit
Compliant with SEMI F19
Medienberührte Teile
VIM-VAR 316L stainless steel, SEMI F20
Sauberkeit
Compliant to ASTM F1374-92 (2005)
Prozessanschluss
Multiple configurations including tube, NPT, Face Seal and Surface Seal
Temperaturbereich
Non-display version: -20OF to 180OF (-29OC to 82OC)
Integrated Display Version:-20°F to 140°F (-29°C to 60°C)
Temperaturkompensation
-4OF to 140OF (-20OC to 60OC) / 68OF to 140OF (20OC to 60OC) 0-10 Vdc version
Lagertemperaturbereich
Non-display: -40OF to 180OF (-40C to 82OC)
Integrated display: -40°F to 167°F (-40°C to 75°C)
Analoge Kommunikation
0-5 Vdc, 0-10 Vdc, 0.2-5.2 Vdc, 2-10 Vdc, 4-20 mA
Versorgungsstrom
Non-display Version: Max. 10 mA
Integrated Display: Max. 30 mA
Benötigte Spannungsversorgung
Display Version:10 to 30 Vdc for 4 to 20 mA output Integrated Display Version:15 to 30 Vdc for 4 to 20 mA output and no signal output
Display Version:11 to 30 Vdc for 0 to 5 Vdc output Integrated Display Version:11 to 30 Vdc for 0 to 5 Vdc output
Display Version: 13 to 32 Vdc for 0 to 10 Vdc output Integrated Display Version:13 to 30 Vdc for 0 to 10 Vdc output
Zertifikate und Zulassungen
EMC: Compliant to EU Directive 2004/108/EC
FM Approved: Non-Incendive for use in Class I, Div II Groups A, B, C and D Hazardous Applications
Einhaltung von Umweltvorschriften
RoHS Directive (2011/65/EU)
REACH Directive EC 1907/2006