Coriolis Sensors and Transmitters |
 Like other Brooks Instrument Coriolis devices, Quantim ® sensors and transmittors offer all the benefits of Coriolis for low flow liquid and low flow gas applications. Quantim sensors provide superb communication flexibility. Combined with Brooks’ newest transmitter, the mass flow sensor lets you access more data in your plant’s process language (Modbus®, HART®, FOUNDATIONTM Fieldbus, PROFIBUS® PA). In addition, multivariable output for mass flow or volumetric flow and density or temperature adds diagnostic capabilities and reduce the need for additional instrumentation. Coriolis Mass Flow Sensor Brooks Quantim (QMBS) Coriolis mass flow sensor offers unsurpassed accuracy and flexibility in low flow liquid and gas measurement applications. The Quantim sensor, combined with Brooks’ newest transmitter, provides superb communication flexibility. It lets the user access more data in the plant’s process language, including Modbus, HART, FOUNDATION Fieldbus, and PROFIBUS PA. Available with three tube sizes to match the customer’s flow measurement needs. It is globally approved for a variety of service areas.
Quantim Flow Transmitters
Brooks Quantim flow transmitters are to be used with Brooks QMBS Quantim Coriolis mass flow sensor. See specifications for more information on transmitter options.
Quantim Mass Flow Sensors
| |
|
|
Nominal Flow1 |
Min Flow |
|
Max Pressure |
Max Temp |
|
| Model |
Type |
Tube Size |
Liquid (Kg/hr) |
Gas (slpm) |
Liquid (Kg/hr) |
Accuracy |
bar |
psig |
C |
F |
Input/Output |
|
|
|
|
|
|
|
|
|
|
|
|
 QMBS |
Precision Mass Flow Sensor Gas and Liquid |
2 3 4 |
0.19 1.00 13.5 |
1.43 5.60 50.4 |
0.001 0.01 0.1 |
±0.2%, 0.5%, or 1.0% Rate |
100 |
1500 |
65 |
150 |
0-5 Vdc or 4-20 mA |
  |
Click here for software tools. 1) Higher flows may be possible depending on the fluid and process conditions.
Quantim Flow Transmitters
| Model2 |
Transmitter Type |
Display |
Number of Outputs |
Available Process Variables |
Output Type |

QTA1
|
Remote Mount
|
Optional |
1 process variable |
Mass or volume flow |
4-20 mA, Frequency, HART or Modbus |
QTA2
|
DIN Rail |
NA |
1 process variable |
Mass or volume flow |
4-20 mA, Frequency, HART or Modbus |
QTA3
|
Remote Mount |
Optional |
Up to 3 process variables |
Mass or volume flow, density, temperature, drive gain |
4-20 mA, Frequency, HART or Modbus |
QTA4
|
Remote Mount |
Optional |
Up to 3 process variables |
Mass or volume flow, density, temperature, drive gain |
4-20 mA, Frequency, HART or Modbus |
QTA5
|
DIN Rail |
NA |
Up to 3 process variables |
Mass or volume flow, density, temperature, drive gain |
4-20 mA, Frequency, HART or Modbus |
QTA6
|
Remote Mount |
Optional |
Up to 3 process variables |
Mass or volume flow, density, temperature, drive gain |
FOUNDATION Fieldbus |
QTA7
|
Remote Mount |
Optional |
Up to 3 process variables |
Mass or volume flow, density, temperature, drive gain |
PROFIBUS-PA |
  |
|